Commercial Pool Equipment: Filtration,
Balance Tanks and Main Drains

Commercial Pool Equipment: Filtration, Balance Tanks and Main Drains

Commercial pool equipment is the mechanical system that keeps a public pool’s water clean, circulating, and safe: filters, water and air quality systems, balance tanks, and main drains. RenoSys supplies commercial pool equipment for new pools and renovations. It also coordinates that equipment with the gutters, drains, and pool systems it manufactures, so the whole recirculation system works together. RenoSys has served commercial and institutional aquatic facilities since 1987. Its equipment line includes D.E. alternative filters, air quality systems, water quality systems, balance tanks, and main drains. Request a free evaluation or call 800.783.7005 to discuss equipment for your pool.
A wide angled shot from the right of the Astoria Park Pool post renovation. Photo courtesy of Timothy Schenck.

What Equipment Does a Commercial Pool Need?

Every commercial pool needs a recirculation system that moves water from the pool, through filtration and treatment, and back again. The table below shows the major components RenoSys supplies and the role each plays. Exact equipment selections depend on the pool’s volume, bather load, indoor or outdoor setting, and local health code. They are coordinated with the project’s mechanical engineer.
Filter pool water without the diatomaceous earth powder media used in traditional D.E. filters
Support the monitoring and treatment that keep pool chemistry within health code requirements
Help manage the air in indoor pools and natatoriums, where airborne byproducts of pool chemistry affect comfort
Hold water displaced by swimmers in gutter-type pools so the water level and recirculation stay steady
Provide the pool’s submerged suction outlets, with covers and configurations that meet federal anti-entrapment requirements

How Does Filtration Fit Into the Recirculation System?

Filtration removes suspended particles from pool water as it circulates. In a commercial pool, the filter is sized for the pool’s volume and required turnover rate. Those are set by the local health code and the design engineer. D.E. alternative filters give facilities another option besides traditional diatomaceous earth filtration. RenoSys can review your existing filter room during a renovation, or coordinate filter selection with the design team on a new pool.

What Does a Balance Tank Do?

A balance tank, sometimes called a surge tank, receives water that flows over the gutter when swimmers enter the pool. It holds that water until the recirculation system returns it. Without it, a gutter-type pool loses water to overflow at peak use and runs low when the pool empties. Balance tanks are common on pools with perimeter gutter systems, including competition and high-use public pools. RenoSys supplies balance tanks and coordinates them with its pool gutter systems so the gutter, tank, and pumps are sized to work together.

What Are the Requirements for Commercial Pool Main Drains?

Commercial pool main drains must meet the federal Virginia Graeme Baker Pool and Spa Safety Act. Under the Act, every public pool and spa has needed compliant anti-entrapment drain covers since December 19, 2008. A pool with a single main drain that is not unblockable also needs a second anti-entrapment device or system, such as a safety vacuum release system or gravity drainage system. That guidance is summarized in CPSC Pool Safely’s VGB Act FAQ. RenoSys supplies main drains for new pools and renovations. It can replace aging drain assemblies while the pool is drained for other renovation work.

How Do Water and Air Quality Systems Help Indoor Pools?

Indoor pools and natatoriums face a problem outdoor pools do not: the air above the water. Byproducts of pool chemistry can build up in enclosed spaces. They affect swimmer and spectator comfort and can corrode building components. RenoSys water quality systems support consistent pool chemistry. Its air quality systems help indoor facilities manage the environment above the water. Both are specified to the facility’s size and use, working with the project’s mechanical engineer. Need a second look at an aging mechanical room? Request a site evaluation or call 800.783.7005.

How Does Equipment Connect with Gutters and Drains?

Equipment performs only as well as the system around it. RenoSys manufactures several components that directly affect how pool equipment works:
  • Integral supply and return gutters. RenoSys gutters combine the trough with pressurized water return inlets. This removes much of the buried return piping and reduces long-term maintenance.
  • Gutter grating. Grating that is cracked or broken restricts flow and creates safety risks. RenoSys grating comes in PVC, HDPE PolyGrate, and granite styles. See pool grating.
  • Deck drains. The DuraTech PVC deck drain moves water off the deck quickly. It comes in lengths up to 20 feet, with custom widths available. See pool deck drains.
Because RenoSys supplies the equipment and the components around it, the design team can coordinate one recirculation system rather than several.

Equipment for New Construction and Renovation

New construction. Equipment is selected and sized alongside the pool system during design. RenoSys coordinates its equipment, gutters, and main drains with the mechanical engineer and general contractor. See new commercial pool construction. Renovation. Many aging pools have equipment that has reached the end of its service life, or buried piping that fails repeatedly. A renovation that includes a new PVC Pool Shell, gutters, and grating is a practical time to replace filters, drains, and balance tanks as well. See commercial pool renovation.

Frequently Asked Questions

What is a D.E. alternative filter?
A D.E. alternative filter is a commercial pool filter that does not use diatomaceous earth powder as its filter media. Facilities consider these filters when they want an option besides traditional D.E. filtration. The right filter type and size depend on pool volume, turnover requirements, and the local health code.
Do commercial pools need a balance tank?
Many do, especially pools with perimeter gutter systems. A balance tank holds water displaced by swimmers so the pool level stays consistent and the gutter keeps skimming properly. Whether a pool needs one, and how large it must be, is set by the pool’s design and the local health code.
What does the Virginia Graeme Baker Act require for main drains?
The VGB Pool and Spa Safety Act requires compliant anti-entrapment drain covers on every public pool and spa drain. Pools with a single main drain that is not unblockable also need a second anti-entrapment device or system. Examples include a safety vacuum release system or gravity drainage system. The CPSC enforces the Act.
Can equipment be upgraded during a pool renovation?
Yes. When a pool is drained for a new interior, gutters, or grating, it is a practical time to replace main drains, filters, and balance tanks. RenoSys evaluates the existing system and recommends which components to upgrade.

Talk to RenoSys About Pool Equipment

RenoSys is family-owned and has more than 38 years of commercial aquatics experience. It helps facilities coordinate equipment, gutters, and pool systems as one recirculation system.

Request a free quote or call 800.783.7005.